Quantcast
Channel: My Nissan Leaf Forum
Viewing all articles
Browse latest Browse all 69396

New "Do-it-yourself" installation EVSE from Aerovironment

$
0
0
by davewill (Posted Mon, 27 May 2013 10:36:43 GMT)
BlacklickBob wrote:
... Unfortunately, the AV unit is hardwired, not a plug-in. Here are two pics, inside the garage, and outside by the meter:
OK, the real electricians around here may have a better solution, but I would do the following (all on the inside of the garage):

    1. Turn off the breaker for this circuit in the service panel.
    2. Dismount the AV unit and disconnect the wires from the AV.
    3. Disconnect and remove the wires that went to the AV from the switch inside the cutoff box.
    4. Remove the short piece of conduit that goes back to the cutoff switch.
    5. Put a proper plug (available at the hardware store) into the hole left by the removed conduit.

That should do it. If anyone wants to use the circuit in the future, all they have to do is run conduit and wire from the cutoff switch to whatever sort of equipment or outlet they want.